Case Study 1
A company has several independent business units that operate globally. The company has consolidated its IT infrastructure services and operations. Common infrastructural services which include IPAM, DNS, NTP, DHCP, and SMTP have been consolidated.
The company has complimented its infrastructure development by investing in Dell EMC Isilon clusters to host its user’s home and group directories and for compliance archival purposes required by individual business units. The IT operations are located in India and the United States with its primary data center facilities co-located between New York and Texas.
The company has a total of 60 AD forests:
– 1 main domain
– 55 domains have one-way trust relationships with the main domain
– An additional 4 domains do not have any trust relationship with no future plans of establishing trust relationships with the other domains.
Users of different AD domains use different FQDN to access their corresponding file services. Additionally, the company does not plan to consolidate the AD domains and each domain uses a different IP subnet.
The users of the domains with no trust relationships have a compliance archival requirement. The company wants to all data to be replicated between New York and Texas.
How many tenant Access zones will be required?
- A . 1
- B . 55
- C . 59
- D . 60
A technician deploy a new server in a datacenter and must install Microsoft Windows Server 2012 R2.
Which two steps are required to install the OS using the Lifecycle Controller? (Choose two.)
- A . Configure storage
- B . Configure Lifecycle Controller network settings
- C . Place OS media in DVD attached to server
- D . Restore server profile
- E . Disable iDRAC virtual media
A technician is investigating a server that is reporting that the Lifecycle Controller is disabled during the power-on procedure.
After checking that the system is displaying no other errors, how can the technician re-enable the Lifecycle Controller?
- A . Access the System Setup utility
Select iDRAC Settings and then select Lifecycle Controller
Check the Enable option, save, and reboot the server - B . Enter the iDRAC GUI
Select iDRAC Settings > Lifecycle Controller
Check the Enable option and then power cycle the server - C . Reboot the server
Press F10 during power up and access the Lifecycle Controller GUI
Select Power On Messages, select Enable, and reboot the server - D . Reboot the server and press Ctrl+L during the power on procedure
At the prompt type “LCC-enable”
Select save and reboot the server
A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and components from other servers are available.
What is the recommended solution?
- A . Use a configuration option to convert an NVMe drive to a virtual vFlash
- B . Use a configuration option to convert BOSS to a virtual vFlash
- C . Reuse an existing vFlash SD card from a 14G server
- D . Reuse an existing vFlash SD card from either a 13G or 14G server
A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and components from other servers are available.
What is the recommended solution?
- A . Use a configuration option to convert an NVMe drive to a virtual vFlash
- B . Use a configuration option to convert BOSS to a virtual vFlash
- C . Reuse an existing vFlash SD card from a 14G server
- D . Reuse an existing vFlash SD card from either a 13G or 14G server
A company’s servers were ordered with iDRAC Enterprise with vFlash. The server profile was backed up after the first boot. Changes have been made to the server BIOS settings and firmware versions, which have resulted in many performance issues.
What is the most efficient way for the technician to address the performance issues?
- A . Upload the approved corporate firmware versions from the file share
- B . Restore system profile using the iDRAC or Lifecycle Controller
- C . Run the racadm racresetcfg command to reset all server settings
- D . Reboot the server to F10 and perform System Repurpose/Retire
A technician configures iDRAC on a new server for access on the management network. When accessing via telnet, the connection is refused. Network connectivity is a verified network. NO ports are blocked by any network devices.
Why is the telnet connection being refused?
- A . Telnet is NOT enabled by default on the iDRAC
- B . The telnet client must be configured to connect to port 8899 on the iDRAC
- C . Telnet is NOT supported to access iDRAC.
- D . The iDRAC must be configured to allow the IP address of the technician’s workstation.
Which front disk chassis option is available in a Dell EMC PowerEdge R740 server?
- A . 4x 3.5" drives
- B . 8x 3.5" drives
- C . 12x 2.5" drives
- D . 24x 2.5" drives
After completing a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster the expense of slowing users down.
Which setting should be changed?
- A . Rebuild Rate in the BIOS settings
- B . System Profile to Performance in the BIOS settings
- C . System Profile to Performance in the iDRAC GUI
- D . Rebuild Rate in the iDRAC GUI
A technician needs to use the iDRAC GUI to roll back a diagnostics firmware revision on a server that was updated four weeks previously. However, the replaced version cannot be found in the Firmware Rollback section on the iDRAC GUI.
What could be the issue?
- A . Diagnostics firmware revision is part of the Lifecycle Controller firmware so the Lifecycle Controller must be updated first
- B . Rollback feature was not enabled in iDRAC Settings
- C . Firmware can only be rolled back within a week of being replaced.
- D . Diagnostics firmware is not supported in the Rollback feature.