DELL EMC D-PDD-DY-23 Übungsprüfungen
Zuletzt aktualisiert am 27.04.2025- Prüfungscode: D-PDD-DY-23
- Prüfungsname: Dell PowerProtect DD Deploy 2023
- Zertifizierungsanbieter: DELL EMC
- Zuletzt aktualisiert am: 27.04.2025
On a PowerProtect DD appliance, which of the following does the system show performance command display?
- A . System performance statistics
- B . System cleaning performance details
- C . Disk I/O performance details for a designated interval
- D . System CPU/Memory performance details for a designated interval
What is one advantage of using PowerProtect DD instead of backing up to other disk-based file systems?
- A . Data is stored locally on the client for fast restore.
- B . Only deduplicated data is sent across the network.
- C . Only deduplicated blocks of data are needed for full recovery.
- D . Data can be restored to any client operating system.
What rule must be followed during an upgrade procedure with the FS25 expansion shelf?
- A . For high performance, the connections from a controller to FS25 shelves must be over FC cables
- B . FS25 shelf is cabled on a separate private chain
- C . FS25 shelf must be on the same chain with DS60
- D . ES40 SAS shelves are on the same chain as an FS25, the maximum number of shelves on that chain is five
When using CIFS from a PowerProtect DD system, what should be changed on a Windows machine?
- A . SMBTimeout to 7200 seconds
- B . CIFSTimeout to 3600 seconds
- C . SESSTIMEOUT to 7200 seconds
- D . SESSTIMEOUT to 3600 seconds
A backup administrator has enabled encryption on a PowerProtect DD appliance. They are attempting to change the passphrase.
What is a consideration when changing the passphrase?
- A . User with the Admin role is sufficient to change the passphrase
- B . User with the Security role is sufficient to change the passphrase
- C . File system must be enabled before changing the passphrase
- D . File system must be disabled before changing the passphrase
A customer requires a backup for their daily operational data. They do not back up directly to the PowerProtect DD appliance using Avamar backup software.
What will be the result of the backup process?
- A . Backup file will be available on cloud tier
- B . Backup server will preserve the data on the PowerProtect DD appliance
- C . Data will be unable to restore locally
- D . Backup process will be using post dedupe technology
What rule must be followed during an upgrade procedure with the FS25 expansion shelf?
- A . FS25 shelf is cabled on a separate private chain
- B . For high performance, the connections from a controller to FS25 shelves must be over FC cables
- C . FS25 shelf must be on the same chain with DS60
- D . If ES40 SAS shelves are on the same chain as an FS25, the maximum number of shelves on that chain is five
Which command displays the RAID group information for the active tier of each shelf?
- A . raid show info
- B . storage show all
- C . filesys show info
- D . raid show all