DELL EMC D-PEMX-DY-23 Übungsprüfungen
Zuletzt aktualisiert am 24.04.2025- Prüfungscode: D-PEMX-DY-23
- Prüfungsname: Dell PowerEdge MX Modular Deploy 2023 Exam
- Zertifizierungsanbieter: DELL EMC
- Zuletzt aktualisiert am: 24.04.2025
What configuration is supported for a fully populated MX740c compute sled?
- A . 1 Fabric B mezz card
1 Fabric C mezz card with Fabric A being integrated into the system board - B . 1 Fabric A mezz card
1 Fabric B mezz card with Fabric C being integrated into the system board - C . 2 Fabric A mezz cards 2 Fabric B mezz cards
2 Fabric C mini-mezz cards - D . 1 Fabric A mezz card 1 Fabric B mezz card
1 Fabric C mini-mezz card
A systems administrator must extract log files from an MX7000. The logs cannot be saved locally and must only be stored on a secure file server.
Which share protocols can they use to save the logs?
- A . NFS and HTTPS
- B . CIFS and NFS
- C . HTTPS and SFTP
- D . HTTPS and SCP
- E . SFTP and CIFS
A technician replaces a failed Management Module in an MX7000 chassis group. After the technician leaves the site, the administrator reports that the lead chassis is no longer able to communicate with its members.
How can OME-M be used to confirm the cabling configuration?
- A . View the health status of the lead Chassis Management Module
- B . View the health status of the lead Chassis Management ports
- C . View the I/O module topology map from the lead chassis
- D . View the topology map from the Group Lead
Refer to the exhibit.
A customer recently replaced all the dual-port network cards in mezzanine A with quad-port network cards across all 16 PowerEdge MX740c sleds in the two-chassis configuration. The customer can only access half of the network ports, even though the quad-port cards are visible in the iDRAC.
What actions are required to resolve the problem?
- A . Do a virtual reseat of all the MX740c sleds.
Update the firmware on all the quad port network cards.
Adjust the switch configuration to use the new ports. - B . Install a new 200G cable from port 3 on the MX7116n in chassis 2 slot A1 into port 19 on the MX9116n in chassis 1 slot A1.
Do the same for the switches in slots A2.
Adjust the switch configuration to use the new ports. - C . Reboot the switches.
Adjust the switch configuration to use the new ports. - D . Reseat all the switches.
Adjust the switch configuration to use the new ports.
An administrator is about to perform a firmware update on an MX9116n switch OS 10 from the CLI. The latest OS 10 switch firmware image has been downloaded and their TFTP server is set up. Upon logged in with administrator credentials on the switch, which command should be used to start the update procedure?
- A . firmwaredownload tftp://server-ip/imagename
- B . install tftp://server-ip/imagename
- C . fwupdate tftp://server-ip/imagename
- D . upgrade tftp://server-ip/imagename
A system administrator must carry out a SupportAssist log collection on an MX750c sled using iDRAC that includes operating system logs.
What is required?
- A . Enterprise License
- B . iDRAC LOM NIC
- C . OpenManage System Administrator
- D . iDRAC Service Module Driver installed
What are the port specifications of the MX8116n FEM?
- A . Two QSFP56-DD interfaces 16 internal 100 GbE server-facing or 8 internal 25 GbE server-facing
- B . Two QSFP56-DD uplink ports 8 internal 100 GbE server-facing or 16 internal 25 GbE server-facing
- C . Four QSFP56-DD interfaces 8 internal 100 GbE server-facing or 16 internal 25 GbE server-facing
- D . Four QSFP56-DD interfaces 16 internal 100 GbE server-facing or 8 internal 25 GbE server-facing
What feature does OME-M v1.3 provide when replacing the Right Control Panel?
- A . Chassis configuration is maintained.
- B . MCM configuration must be reconfigured.
- C . Chassis configuration must be reconfigured.
- D . MCM configuration can be backed up in the cloud.
An MX7000 administrator has been tasked to create a Scalable Fabric Architecture on a 3 chassis setup using Fabric B.
Which IOM configuration is recommended?
- A . Chassis 1 C Slot B1: MX9116n; Slot B2: MX9116nChassis 2 C Slot B1: MX5108n; Slot B2: MX5108n
Chassis 3 C Slot B1: MX5108n; Slot B2: MX5108n - B . Chassis 1 C Slot B1: MX7116n; Slot B2: MX7116nChassis 2 C Slot B1: MX7116n; Slot B2: MX7116n
Chassis 3 C Slot B1: MX9116n; Slot B2: MX9116n - C . Chassis 1 C Slot B1: MX9116n; Slot B2: MX7116nChassis 2 C Slot B1: MX7116n; Slot B2: MX9116n
Chassis 3 C Slot B1: MX7116n; Slot B2: MX7116n - D . Chassis 1 C Slot B1: MX9116n; Slot B2: MX5108nChassis 2 C Slot B1: MX5108n; Slot B2: MX9116n
Chassis 3 C Slot B1: MX5108n; Slot B2: MX5108n
What does OBPAR allow on a PowerEdge MX750c?
- A . Run a compute sled with memory overclocking.
- B . Boot a compute sled with only one CPU.
- C . Run a compute sled with maximum performance.
- D . Boot a compute sled with reduced frequency.