DELL EMC D-VXR-DY-01 Übungsprüfungen
Zuletzt aktualisiert am 27.04.2025- Prüfungscode: D-VXR-DY-01
- Prüfungsname: Dell VxRail Deploy Exam
- Zertifizierungsanbieter: DELL EMC
- Zuletzt aktualisiert am: 27.04.2025
An implementation engineer is working with a customer to prepare an external vCenter Server for a new VxRail deployment with customer-supplied VDS.
What vCenter objects must exist for a successful VxRail deployment?
- A . Datacenter, Cluster, and Custom VDS
- B . Datacenter, VxRail Management user, and Custom VDS
- C . Datacenter and VxRail Management user only
- D . Datacenter, Cluster, and VxRail Management user
A VxRail cluster has just been deployed. The administrator notices that Deduplication and Compression are not enabled.
What is the reason for this issue?
- A . The VSAN licensing is missing
- B . The service is disabled by default
- C . Nodes are configured with hybrid drives
- D . Nodes are configured with a single disk group
An implementation engineer has just completed the deployment of a new VxRail cluster. They are unable to connect to the vCenter Server.
What can they use to confirm the physical health of the VxRail nodes?
- A . vSphere Client
- B . SRS
- C . VxRail Manager
- D . iDRAC
A system administrator attempts to use the VxRail REST API to obtain system health status for their VxRail environment. The system returns the following error code: 401.
What should the administrator do to address this issue?
- A . Provide vCenter credentials with sufficient rights
- B . Ensure that the VxRail Manager IP address is correct
- C . Use a REST API software package different than the native version of swagger
- D . Use /v2/system instead of /v1/system
What is a consideration when using ToR switches with VxRail?
- A . IPv6 Multicast must be disabled in this environment.
- B . Link aggregation must be enabled on VxRail switch ports.
- C . VxRail iDRAC Management ports require 10 GbE ports.
- D . All-Flash models must use 10 GbE or faster ports.
A new enterprise customer will be deploying VxRail, utilizing an existing vCenter.
Which server will be used to add and validate the host and domain names?
- A . Internal DNS server deployed on node1
- B . Customer external DNS server
- C . Customer external vCenter with host file
- D . Internal DNS server on VxRail Manager
An implementation engineer is in the validation phase of a VxRail deployment with two Dell EMC ToR switches.
Which command should they run on each of the ToR switches to validate that Link Aggregation has been configured according to Dell best practices for VxRail node interfaces?
- A . show network-policy profile
- B . show interface
- C . show port-channel summary
- D . show interface status
When using VxRail Manager, what is the source of information that can help validate good VxRail system post-deployment status?
- A . Last Heartbeat, Last Configuration Sent, Network Environment Settings, Cluster Monitor
- B . System Diagnostic, Events, Health Logical View, Health Physical View, Log Bundle
- C . MARVIN-Virtual-SAN-Cluster > Manage > Health and Performance
- D . MARVIN-Virtual-SAN-Cluster > Monitor > Virtual SAN > Health
An implementation engineer has just finished connecting a multi-rack VxRail cluster over a Layer 3 network. When attempting to migrate System VMs from the first rack to the second rack, they receive an error.
What is a possible reason for the error?
- A . vSphere DRS must be enabled
- B . System VMs must be on different subnets
- C . Only Layer 2 networking is supported
- D . System VMs must be on the same subnet
Which requirement must be met when expanding a 3-node VxRail G560F cluster with a fourth G Series node in the same chassis?
- A . PCIe network card must be added to all nodes
- B . Node requires only the same drive configuration
- C . Node hardware must be identical to the other three nodes
- D . New node must be at the same VxRail version as existing nodes