DELL EMC D-VXR-OE-01 Übungsprüfungen
Zuletzt aktualisiert am 26.04.2025- Prüfungscode: D-VXR-OE-01
- Prüfungsname: Dell VxRail Operate v2 Exam
- Zertifizierungsanbieter: DELL EMC
- Zuletzt aktualisiert am: 26.04.2025
What is the benefit of using VxRail Appliance REST API?
- A . It simplifies hardware upgrades.
- B . It allows for remote management of the system.
- C . It enables automation of routine tasks.
- D . It provides enhanced security features.
A VxRail system administrator has been tasked to add the support account to all of the 50 VxRail clusters. The administrator is using API calls but is receiving 403 error codes.
What is the likely issue?
- A . Call has failed with internal errors
- B . Username/password is not recognized
- C . User account does not have sufficient privileges
- D . Support account credentials provided are not valid
What backup options are supported by VxRail Manager?
- A . Local only
- B . Cloud-based
- C . Both local and cloud-based
- D . None, as it requires third-party software
An environment has two VxRail clusters with the following hardware configuration:
– Cluster-A is using FTT = 2 and FTM = Erasure Coding
– Cluster-B is using FTT = 2 and FTM = Mirroring
A 100 GB VM is planned to be vMotioned from Cluster-A to Cluster-B.
How much more vSAN capacity is consumed in Cluster-B than in Cluster-A?
- A . 0 GB; consumption is unchanged
- B . 100 GB
- C . 150 GB
- D . 167 GB
A VxRail administrator wants to download the last configuration data sent using Secure Remote Services.
Where in the interface would the administrator find this option?
- A . Hosts and Clusters > Right-click the Cluster > VxRail > Download Configuration Data
- B . Hosts and Clusters > Right-click the Cluster > VxRail > Last Configuration Data Sent > Download
- C . Hosts and Clusters > Cluster > Monitor > VxRail > Appliances > Last Configuration Data Sent > Download
- D . Hosts and Clusters > Cluster > Monitor > VxRail > Last Configuration Data Sent > Download
What is the maximum number of racks supported when expanding a VxRail cluster beyond a single physical rack?
- A . 2
- B . 4
- C . 6
- D . 8
An administrator must add an additional network card to an existing set of VxRail nodes in their infrastructure. After the network card has been added to each node, the administrator does not see them in use in vCenter.
What must the administrator do to use the newly added uplinks?
- A . Add uplinks to the virtual standard switch
- B . Use LCM to update NIC Drivers
- C . Use esxcli to install necessary VIBs
- D . Add uplinks to the virtual distributed switch
An administrator is tasked with remediating the identified security vulnerabilities in the VxRail cluster. The administrator needs more information to resolve the security issues.
What should be used to gather the required information?
- A . Advisories
- B . Event Codes
- C . Health Analyzer
- D . Skyline Health
SIMULATION
An existing 4-node VxRail standard cluster has to be scaled out with 2 additional nodes and configured as a stretched cluster.
An administrator must prepare a vSAN storage policy that should have the following:
– vSAN Policy Name: vSAN Stretched Cluster
– Data protection across the sites
– Local protection: RAID-1 with FTT=1
– Thick Provisioning
An administrator should be able to provision a VM even if the currently available cluster resources cannot satisfy the current policy.
Use the simulator to create the required vSAN storage policy.
A VxRail cluster needs to be moved to a new rack in the datacenter. During this process, the entire cluster will be temporarily shut down.
Which Maintenance Mode option is the best fit?
- A . Protected maintenance mode
- B . Ensure accessibility
- C . Full data migration
- D . No data migration