Netapp NS0-014 Übungsprüfungen
Zuletzt aktualisiert am 26.04.2025- Prüfungscode: NS0-014
- Prüfungsname: NetApp Implementation Engineer MetroCluster Specialist (NCIE-MetroCluster)
- Zertifizierungsanbieter: Netapp
- Zuletzt aktualisiert am: 26.04.2025
Which two tasks are performed by the MetroCluster Tiebreaker software? (Select two)
- A . Monitors cluster health
- B . Synchronizes data across nodes
- C . Manages site failover
- D . Configures SyncMirror
In a MetroCluster environment, which two steps are required to configure FC switches? (Select two)
- A . Enable NPIV (N-Port ID Virtualization)
- B . Configure VSANs for all switches
- C . Configure IPsec for secure communication
- D . Set up inter-switch links (ISLs) between the FC switches
What are the primary tools used for troubleshooting a MetroCluster environment? (Choose two)
- A . Config Advisor
- B . SnapVault
- C . OnCommand System Manager
- D . ATTO Diagnostics
What is a critical requirement for transitioning a MetroCluster environment from 7-Mode to Clustered ONTAP?
- A . Reconfiguring IP switches
- B . Using the 7-Mode Transition Tool
- C . Replacing all storage hardware
- D . Manually updating all ONTAP licenses
What is the primary role of the ATTO FibreBridge in a MetroCluster configuration?
- A . Convert IP to Fibre Channel traffic
- B . Provide redundancy for network paths
- C . Connect disk shelves to controllers
- D . Optimize network performance
Which ONTAP feature allows MetroCluster administrators to non-disruptively upgrade their environment to a new ONTAP version?
- A . SnapVault
- B . Automated Non-Disruptive Upgrade (NDU)
- C . SVM DR
- D . SnapMirror
What are two critical tasks to perform when validating a MetroCluster configuration after an upgrade? (Select two)
- A . Verify SyncMirror status
- B . Test storage failover operations
- C . Reconfigure ATTO FibreBridges
- D . Run a Tiebreaker simulation
What are two methods used to test failover in a MetroCluster configuration? (Choose two)
- A . Powering off a storage node
- B . Running the metrocluster switchover command
- C . Shutting down an FC switch
- D . Disconnecting the Mediator
If the metrocluster check command returns errors, what is the most likely next step?
- A . Reinstall MetroCluster
- B . Analyze the error logs in Config Advisor
- C . Perform a manual switchover
- D . Replace the storage controllers
What are two benefits of transitioning from an FC-based MetroCluster to an IP-based MetroCluster? (Select two)
Lower hardware costs due to fewer FC components
Increased storage capacity
Easier long-distance replication
Faster sync replication